MEP 660 - Trouble shooting Manual
Doc No.: IM – 51
Rev.2.0
Print: October 2008
183
PARAMETER
DESCRIPTION
FAULT CODE
1177
FAULT MESSAGE Engine Tacho Output Noisy
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
High, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
RECOVERY
Manual only
PROBABLE
CAUSES
1. Noisy output from tacho generator continuously.
FAULT
ISOLATION
1. Reset the fault manually.
2. Check up the tacho generator for any loose connections or loose
magnets on the rotor etc. Replace the tacho generator if necessary.
PARAMETER
DESCRIPTION
FAULT CODE
1178
FAULT MESSAGE Engine Tacho Output Noisy
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
High, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
RECOVERY
Manual only
PROBABLE
CAUSES
1. Noisy output from tacho generator.
FAULT
ISOLATION
1. Reset the fault manually.
2. Check up the tacho generator for any loose connections or loose
magnets on the rotor etc. Replace the tacho generator if necessary.