MEP 660 - Trouble shooting Manual
Doc No.: IM – 51
Rev.2.0
Print: October 2008
255
PARAMETER
DESCRIPTION
FAULT CODE
1254
FAULT MESSAGE Altitude Sensor Faulty
RESTRICTIONS
--
ALARM BELL
--
RESET LEVEL
MEDIUM, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
RECOVERY
Automatic when the Altitude sensor found working normal.
PROBABLE
CAUSES
1. Altitude sensor APR faulty.
2. Defective cables
3. Defective ADB2
5. Defective MAIP8_AU card in slot 1.
FAULT
ISOLATION
1. Set the display to show ixed parameters by selecting ‘Display’
mode from the main menu and then selecting ‘Mixed’ sub-menu.
2. Check the altitude displayed in the display unit with Actual altitude
of the site.
3. If the difference is excess, replace the sensor and check up.
4. If the difference is negligible but still the fault is logging frequently:
A. Check Slackness of the connectors either at the sensor or at the
ADB1. Tighten the connectors both at the sensor and ADB of the
cable ID: BG.
B. Defective interconnecting cable ID: BG between sensor and
ADB. Replace the cable and check up.
C. Slackness of the connectors either at ADB2 or MEP-660 control
unit. Tighten the cable connectors both at ADB2 and MEP-660
control unit for the cable ID: AI.
D. Defective interconnecting cable ID: AI between ADB and MEP-
660 control unit.
E. Defective ADB2. Replace the ADB2 and check.
F. Defective MAIP8_WS card in slot 1. Replace the card check up.