MEP 660 - Trouble shooting Manual
Doc No.: IM – 51
Rev.2.0
Print: October 2008
223
PARAMETER
DESCRIPTION
FAULT CODE
1216
FAULT MESSAGE AUX. EEPROM Write Error at Power Off. Last AUX Fault Cleared.
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
High, Manual
FAULT
RECOVERY
--
PROBABLE
CAUSES
System is switched off while writing the fault message on the EEPROM.
FAULT
ISOLATION
--
PARAMETER
DESCRIPTION
FAULT CODE
1217
FAULT MESSAGE Life Time Loco Data Counters Faulty and they are Reset
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
Medium Manual
FAULT
RECOVERY
Manual only (By using Laptop / PC)
PROBABLE
CAUSES
--
FAULT
ISOLATION
--
PARAMETER
DESCRIPTION
FAULT CODE
1218
FAULT MESSAGE Life Time Loco Data counters Start. Date/Time Faulty and Counters Will
be Reset at next Time Setting
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
Medium Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
RECOVERY
Automatic when time is set.
PROBABLE
CAUSES
--
FAULT
ISOLATION
Through configuration software, date and time has to be update by
using Laptop / PC.