MEP 660 - Trouble shooting Manual
Doc No.: IM – 51
Rev.2.0
Print: October 2008
117
3.0.
MEDIUM PRIORITY FAULTS
PARAMETER
DESCRIPTION
FAULT CODE
1118
FAULT MESSAGE Excess Traction Motor 1 Current. Maximum TM current limited.
RESTRICTIONS
Maximum TM Current LIMITED.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
RECOVERY
Automatic when traction motors get cooled.
PROBABLE
CAUSES
1. Driver might have worked more time than the stipulated time in the
restricted zone of the load meter.
FAULT
ISOLATION
1. The fault will get reset automatically.
PARAMETER
DESCRIPTION
FAULT CODE
1119
FAULT MESSAGE Excess Traction Motor 2 Current. Maximum TM current limited.
RESTRICTIONS
Maximum TM Current LIMITED.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
RECOVERY
Automatic when traction motors get cooled.
PROBABLE
CAUSES
1. Driver might have worked more time than the stipulated time in the
restricted zone of the load meter.
FAULT
ISOLATION
1. The fault will get reset automatically.