IDC Receive Data Register (IDC_RX_DATA)
Offset = 0xBE008C
Read Only
Default = 0x0000 0000
RxData
Receive Data
[23:16]
Reading this location reads data from the 8-byte RX
FIFO. Data is placed in the RX FIFO when the IDC
device is either the master of a valid read, or the slave of
a valid write.
Caution:
Do not read more bytes from this register than the number
indicated in the RxCnt field of the IDC FIFO Fullness
register. Attempting to read more bytes than are available
will corrupt the RxCnt value, requiring a software reset.
31
24
23
16
Reserved
RxData
15
0