6: Context sensitive help
Status: Port Summary
Background Information
Shows all ports used in the receiver configuration for data streams, remote access (OWI), FTP and web interface
access. For each port the connection status and use case is displayed.
Field Description
The table below describes the fields on the Status: Port summary page.
Press the
Refresh icon
to update the displayed information.
Data Ports
Description
Icon
An icon is shown, indicating the data stream connection status.
Disconnected
Connecting
Awaiting connection(s)
Connected
Data connections:
Port
The connection type, port number and mountpoint (for NTRIP connections)
configured for the data stream.
# Connections
The number of connected users on each port. With the default setting, a maximum of
one user is possible.
If the Multi-Client option is installed on the receiver and the configuration is set
accordingly, more than one connection per TCP/IP port is possible. In this case, the
number of connected users and the number of possible connections is shown.
Host / Duration
The IP address of the client/server connected to the TCP/IP port.
If there are multiple connections to the port, the longest connection is shown.
Click on the IP address to open a pop up window. The pop up window shows the
data volume sent and received on this port and lists all connected host IPs and the
connection duration.
Data type
The data type transmitted by the port.