6: Context sensitive help
Logging session wizard: Compact RINEX (Hatanaka)
Setting Descriptions
The table below describes the settings that can be configured on the Compact RINEX (Hatanaka) page.
Setting
Description
Logging rate
Select the rate at which the observations are to be logged.
Note:
A faster logging rate results in higher resource consumption on the
receiver.
Length of file
Choose a value from 5 minutes to 24 hours.
The file length defines how long data is written to one file before a new file is
created.
Dynamics
Raw data for the Compact RINEX logging session can be logged in static or
moving (kinematic) mode.
Operator
Enter the name of the operator that is to appear in the RINEX file header.
•
Maximum number of characters allowed is 20.
•
Only certain
ASCII characters
are allowed.
0123456789
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz
- _ and a "space" are allowed.
•
If left empty, the field in the RINEX header will be left blank.
Agency
Enter the name of the agency that is to appear in the RINEX file header.
•
Maximum number of characters allowed is 40.
•
Only certain
ASCII characters
are allowed.
0123456789
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz
- _ and a "space" are allowed.
•
If left empty, the field in the RINEX header will be left blank.
Include SNR values
Activate to include the (unmapped) SNR observations in the Compact RINEX file.
Log doppler
observations
Activate to include the doppler observations in the Compact RINEX file.