4: User Interface
31
Recommended user action:
Immediately activate the
Smart clean-up or the automatic file delete for each
logging session.
Raw data
logging LED
off
No active logging sessions or power is off.
green
Active logging sessions are configured on the instrument and data is
being logged.
yellow
Active logging sessions are configured but Smart clean-up is deleting
data from all or some of the configured logging sessions.
OR
Active logging sessions are configured but no position is available.
Recommended user action:
Check the remaining
space on the SD card and delete old data if necessary.
Check the tracking and position status.
red
Active logging sessions are configured but the SD card is full or no
navigated position is available.
Recommended user action:
Check the SD card and
the tracking status.
RT out data
stream LED
off
No active real-time out data stream or power is off.
green
One or more real-time data streams are configured and active. Data is
being streamed.
red
Data streams are active but no data is streamed.
Recommended user action:
Check that data is
tracked and a navigated position is available. Check
that the correct reference position is entered.
RT in data
stream LED
-
Currently not supported.
Position LED
off
The instrument is switched off.
flashing
green
The instrument is tracking satellites but no position is available.
green
A navigated position is available.
red
No satellites are tracked and no navigated position is available.