The RED button is used for disarming from either home or away modes, so that there is no need for the owner to recall
which mode the system has been armed in.
The Panic feature is activated by pressing the GREEN & BLUE buttons together.. This sets off the siren.
To cancel “panic”, press the RED disarm button.
Wiring the 236i - WRX to your C & K 236i Panel
Narrowband Wireless Receiver with 2 x Code Hopping Remote
Controls
Green: ARM
Red: DISARM
Blue: Activate HOME Mode
To Activate Panic Mode,
Press Green & Blue Buttons
Together
10: Fault Output (Supervision / Low Battery) - Zone 6
9: Tamper Output (Open Case of PIR / Reed)
8: Available Wireless Zone Output - (Zone 5)
7: Wireless Smoke Sensor Output - (Zone 4)*
6: Wireless PIR Output (Zone 3)*
5: Wireless PIR Output (Zone 2)*
4: Wireless PIR Output (Zone 1)*
3: Keypad Data Output - Connect to
DATA
2: Connect to
C
1: Connect to
KEY+
Antenna Wir
e
:
Do Not Cut.
Optimum operation
range will be
achieved when
antenna is vertical &
straight. Run the wire
out of the top of your
metal panel box.
N517
Build Date:
Sticker showing User PIN Number (Refer to Page 2 for details).
•
* When purchasing the 236i - WRX Kit, sensors supplied in the kit will be pre-programmed as detailed
above.
NOTES:
1) Your 236i Panel should use the default Master PIN Number 1234.
2) The 236i - WRX uses the fixed keypad address 11.
1
3) The 236I - WRX already has inbuilt 2k2 end of line resistors, so no additional
WARNING! - Do Not Have Another Keypad On The Same Address
resistors need to be configured on the zone panel inputs.
4) You must enter the User PIN Number for your receiver, as detailed on Page 2.