SUPERVISION
All of your individual wireless detectors (PIR's, Reeds or Smoke Detectors) can send a supervision report to your 236i -
WRX receiver to confirm that they are fully functional.
If you have purchased the 236i Kit, supervision has already been enabled for each detector programmed in at the factory.
NOTE: If you remove a detector, you must disable the supervision report for that channel, otherwise the fault output will be
activated as detailed below.
If supervision mode is enabled for a particular channel, the receiver will be expecting to receive the supervision code from
the detector learnt into that respective channel every 2.4 hours i.e. at least 10 reports per day, per detector.
The 236i - WRX only requires one report from each detector during the 24 hour period to satisfy the supervision criteria. An
extra 9 reports are still given to ensure that the supervision report is received.
If all 10 supervision reports are missed from one detector during the 24 hour time frame, then the fault output will be
activated (it will switch low for 2 seconds).
TURNING SUPERVISION REPORTS ON OR OFF FOR CHANNELS 2 - 6
(Zones 1 - 5)
1. Enter programming mode.
2. Select Channel 12.
3. Via FEATURE MODE lights, press the GREEN Button to select the desired Channel / Zone that you wish to enable or
disable supervision for as shown in diagram below.
FLASHING MODE LIGHTS indicate supervision is OFF for that Channel / Zone.
MODE LIGHTS ON indicate supervision is ON for that Channel / Zone.
4. Select first the lowest Channel / Zone that you wish to change the supervision setting for, press the RED button on your
remote to toggle the LED lights from ON to Flashing, depending on whether you wish to enable or disable supervision
for that Channel / Zone.
5. Press the green button to move to the next channel as per Step 3, if there is another Channel / Zone that you wish to
enable / disable supervision. NOTE: Once you have passed Channel 7, you will not automatically loop back to Channel
2 / Zone 1. You must exit supervision programming & restart procedure.
6. To exit supervision programming mode, hold down the GREEN button until the LED’s begin to scroll again (approx. 5
sec).
LOW BATTERY & TAMPER WARNING
CHANNEL 12
8
4
2
1
Channe1 2 / Zone 1
4
2
1
Channel 4 / Zone 3
4
2
1
Channel 5 / Zone 4
4
2
1
Channel 3 / Zone 2
4
2
1
Channel 6 / Zone 5
4
2
1
Your detectors will automatically transmit a low battery report to your 236i - WRX receiver when the batteries are nearly
flat.
The low battery report code is transmitted every time a detector sends a supervision report, or whenever the detector is
triggered.
6