Malfunction, cause and remedy
19
Faults of the electrics/electronics
19.5
Comprima F 155 XC
Original Operating Instructions 150001050_01_en
243
522020-
Chamber film wrapping
Possible cause
Remedy
FMI 7: The film is not transported when the tying process has started.
The film roll is empty.
Change the film roll,
The film roll has the wrong di-
mensions.
Use only film rolls with the prescribed dimensions,
The film roll has not been cor-
rectly inserted into the roll
holder.
Insert the film roll according to the description,
The brake force release has
not been set correctly.
Check and set the brake force release during the feed
process,
.
The film has not been cor-
rectly inserted.
Insert the film according to the description,
.
The film overhang is too short.
Check the film overhang. Ensure that it is at least 250 mm.
If the film overhang is too short, adjust the wire rope,
The brake force release has
not been set correctly.
Check and set the brake force release during the feed
process,
.
The wrapping material brake
does not release.
Adjust the wrapping material brake,
Check the axial play of the wrapping material brake,
The film is pulled earlier even
though the feed rocker arm is
not yet in the feed position.
Check the sensor B02 "Tying process active".
Check the sensor B61 "Tying 1 (passive)" and set the feed
position,
The rotational speed is too
high.
Check the rotational speed. It must not be higher than 540
rpm.
The inserted film is pulled out
of the retaining comb.
To keep the film taut, adjust the end position,
The feed strips on the retain-
ing comb are not correctly fed.
Check the spring tension of the retaining comb,
Check the feed strips for damage. If required, have new
blue strips ordered and mounted by the KRONE service