19
Malfunction, cause and remedy
19.5
Faults of the electrics/electronics
228
Comprima F 155 XC
Original Operating Instructions 150001050_01_en
Acknowledging error message
Note down the error message.
Briefly press on
.
Æ
The acoustic signal stops and the error display is no longer indicated. If the fault occurs
again, the error message will be displayed again.
To acknowledge the error message until the operating terminal is next started, press and
hold down the
key for 5 seconds.
Rectify the error,
.
Acknowledge and still pending error messages can be displayed again via the status line,
.
19.5.1.1
Possible error types (FMI)
There are different types of errors which are shown under the term FMI (Failure Mode
Identification) with an appropriate code.
FMI
Meaning
0
The upper limit value was greatly exceeded.
1
The lower limit value was far below the required one.
2
The data is not permitted.
3
There is an overvoltage or a short circuit to supply voltage.
4
There is an undervoltage or a short circuit to ground.
5
A cable is broken or amperage is too low.
6
There is a short circuit to ground or amperage is too low.
7
The mechanics do not respond or the expected result was not achieved.
8
The frequency is not permitted.
9
There is an abnormal update rate.
10
There is an abnormal rate of change.
11
The error cause is unknown.
12
There is an internal error.
13
The values of the calibration are outside the value range.
14
Particular instructions are required.
15
The upper limit value has been reached.
16
The upper limit value has been exceeded.
17
The lower limit value has been reached.
18
The lower limit value has not been reached.
19
There is a CAN communication failure.
20
The data deviates upwards.
21
The data deviates downwards.
31