Commissioning
7
Connecting KRONE BETA II terminal
7.10
Comprima F 155 XC
Original Operating Instructions 150001050_01_en
61
Tractors without ISOBUS system
8
B290
3
5
6
7
4
2
1
EQ003-252
ü
The machine is shut down and safeguarded,
.
ü
The machine is shut down and safeguarded, refer to chapter Safety “Shutting down and
safeguarding the machine” in the operating instructions of the machine.
ü
The accessories kit B290 “KRONE tractor retrofitting” is mounted.
Connection terminal to tractor
Connect the 9-pin plug (2) of the cable (1) to the 9-pin socket (3) (In-cab).
Connection tractor to machine
INFORMATION
The cable (6) can be ordered by quoting the order number 20 086 886 *.
Connect the 9-pin plug (5) of the cable (6) to the 9-pin ISOBUS socket (4) of the tractor.
Connect the 11-pin plug (7) of the cable (6) to the 11-pin socket (8) of the machine.
7.10
Connecting KRONE BETA II terminal
NOTICE
Short circuit caused by impurities and moisture in the plug connection
The machine may be damaged by a short circuit.
Make sure that the plugs and sockets are clean and dry.