19
Malfunction, cause and remedy
19.5
Faults of the electrics/electronics
246
Comprima F 155 XC
Original Operating Instructions 150001050_01_en
522024-
Net wrapping
Possible cause
Remedy
FMI 7: The net is not, or not cleanly, cut.
The cutting unit is blunt.
Remove deposits from the cutting unit.
If required, have the cutting unit replaced by a KRONE
service partner.
The cutting unit is not actu-
ated.
Remove deposits from the cutting unit.
Check that the blade lever rotates.
Check and adjust the wrapping material overhang,
The actuator for wrapping pro-
cess is defective.
Check the actuator for wrapping process.
The ratchet on the cutting unit
does not move upwards.
Check the wire rope on the cutting unit and, if required,
shorten.
522024-
Chamber film wrapping
Possible cause
Remedy
FMI 7: The film is not, or not cleanly, cut.
The cutting unit is blunt.
Remove deposits from the cutting unit.
If required, have the cutting unit replaced by a KRONE
service partner.
The cutting unit is not actu-
ated.
Remove deposits from the cutting unit.
Check that the blade lever rotates.
Check and adjust the wrapping material overhang,
The actuator for wrapping pro-
cess is defective.
Check the actuator for wrapping process.
The ratchet on the cutting unit
does not move upwards.
Check the wire rope on the cutting unit and, if required,
shorten.
522035-
MAX
Filling the bale chamber
Possible cause
Remedy
FMI 0: The maximum filling of the bale chamber has been reached. The round bale is forcibly
tied, even if it should be manually tied. This may damage the machine in the long term.
Too many crops loaded too
quickly into the bale chamber.
Reduce the driving speed earlier and adjust to the swath.
Advance signalling has not
been set.
Set advance signalling,
.
Advance signalling has been
ignored and the bale chamber
loaded with too many crops.
Observe advance signalling.
Do not permanently overload the bale chamber.