19
Malfunction, cause and remedy
19.5
Faults of the electrics/electronics
242
Comprima F 155 XC
Original Operating Instructions 150001050_01_en
522013-
Blade cassette
Possible cause
Remedy
FMI 7: The blade cassette has not been lifted and the universal shaft is active.
The blade cassette has not
been swivelled in.
Swivel in the blade cassette via the tractor hydraulics.
The sensor B08 "Blade cas-
sette up" is defective or is not
correctly set.
Check and set the sensor B08 "Blade cassette up",
522020-
Net wrapping
Possible cause
Remedy
FMI 7: The net is not transported when the tying process has started.
The net roll is empty.
Change the net roll.
For "Net wrapping" version:
For "Net and chamber film wrapping" version
The net roll has the wrong di-
mensions.
Only use net rolls with the prescribed dimensions,
The net roll has not been cor-
rectly inserted into the roll
holder.
Insert the net roll according to the description.
For "Net wrapping" version:
For "Net and chamber film wrapping" version:
The net has not been correctly
inserted.
Insert the net according to the description.
For version with "Net wrapping":
For version with "Net wrapping and chamber film wrapping":
.
The net overhang is too short.
Check the net overhang. Ensure that it is at least 250 mm.
If the net overhang is too short, adjust the wire rope,
The wrapping material brake
does not release.
Adjust the wrapping material brake,
Check the axial play of the wrapping material brake,
The brake force release has
not been set correctly.
Check and set the brake force release during the feed
process,
.
The net is pulled earlier even
though the feed rocker arm is
not yet in the feed position.
Check the sensor B02 "Tying process active".
Check the sensor B61 "Tying 1 (passive)" and set the feed
position,
The rotational speed is too
high.
Check the rotational speed. It must not be higher than 540
rpm.