Condition Code: 27-601 – Invalid Power Monitor Offset
Condition Code: 27-604 – Unable to Adjust Laser Dynamic Range
Web Portal Message
Log Message
DICOM Printer
StatusInfo
Severity
Optics: Calibration
Failed
Optics Calibration
Failed. Power Monitor
Offset outside valid
range.
ELEC DOWN
0-Fatal
Description
This error occurs when the power monitor offset measured by the optics
calibration and diagnostics is outside the predefined valid range.
The error clears when a calibration is requested or power is cycled.
System Impact
The imager can only print jobs that were in process when the error occurred.
The spooler can still accept jobs, but the jobs will not print until the error is
resolved. All jobs that were in process when the error occurred will reprint
completely when the error is resolved. [SI-1]
User Action
1. Shut down the laser imager, and then restart the imager.
2. If the error persists, call for service.
Show at DS
True
DICOM Printer
Status
FAILURE
Unique Symb. ID
ERR_INVALID_POWER_MONITOR _OFFSET
Logged for RMS
[TriggerValues=x][TriggerRange=y,z][TriggerNotes=Power Monitor Offset:
value, limits]
Web Portal Message
Log Message
DICOM Printer
StatusInfo
Severity
Optics: Calibration
Failed
Optics calibration failed
to Adjust Laser
Dynamic Range within
limits
ELEC DOWN
0-Fatal
Description
This error occurs when the laser dynamic range measured by the optics
calibration and diagnostics is outside the predefined valid range after 5
successive adjustment attempts.
The error clears when a calibration is requested or power is cycled.
System Impact
The imager can only print jobs that were in process when the error occurred.
The spooler can still accept jobs, but the jobs will not print until the error is
resolved. All jobs that were in process when the error occurred will reprint
completely when the error is resolved. [SI-1]
User Action
1. Shut down the laser imager, then restart the laser imager.
2. If the error persists, call for service.
Show at DS
True
DICOM Printer
Status
FAILURE
Unique Symb. ID
ERR_CANT_ADJUST_LASER_DYNAMIC_RANGE
Logged for RMS
[TriggerValues=x][TriggerRange=y,z][TriggerNotes=Laser Dynamic Range:
value, limits]