Electrical Adjustments
SM3226-1 – 10FEB97
5–99
[13] Enter [P] [M] [R].
Note
The number of pulses entered depends on the distance
the ROLLER SHAFT must be moved.
[14] Enter a negative pulse number to move the
ROLLER toward the STOPPER and a positive
pulse number to move the roller away from the
STOPPER.
[15] Enter [1] [0] for the speed.
[16] Repeat Steps 13 - 15 until the ROLLER SHAFT
lines up with the holes in the FRONT and REAR
MECH PLATES and contacts the TRANSPORT
ROLLER.
error=0
Enter Command: PMR
Pulse number? (-30000 to 30000)[0]: -10
Speed? (10 to 1500 pps) [10]: 10