Electrical Adjustments
SM3226-1 – 10FEB97
5–91
Receive Side Stopper Position
To Check:
[1] Connect the PORTABLE COMPUTER.
[2] Open the RECEIVE MAGAZINE DOOR.
[3] Open the USER ACCESS DOOR.
[4] Rotate the KEYSWITCH to the ON position.
[5] Use the PORTABLE COMPUTER to display the
CES Main Menu.
[6] Enter [1] for “Monitor Mode”.
[7] Enter [7] for “Enter Commands”.
Note
• Commands must be entered using capital letters.
• See the Diagnostics section to clear any error
messages displayed on the PORTABLE
COMPUTER during this procedure.
[8] Enter [I] [T] [R] to initialize the TRANSPORT
ROLLER.
[9] Enter [P] [M] [R].
[10] Enter [-] [2] [8] [1] for the pulse number.
[11] Enter [4] [4] [4] for the speed.
[12] When the ROLLER hits the STOPPER, check
that the ROLLER SHAFT is centered in the
FRONT and REAR MECH PLATE holes and
contacts the TRANSPORT ROLLERS.
MAIN MENU
1 Monitor Mode 4 System Params
2 System Logs 5 Debug Utility
3 Boards Diag 6 Exit
Enter Menu Item:
MONITOR MODE MENU
1 Motors 6 Seq Board Diag
2 Solenoids 7 Enter Commands
3 Relay 8 Set Beam-Splitter
4 Miscellaneous 9 Auto Sensor Test
5 Sensors 10 Semi-Auto Sensor Test
Enter Menu Item:
Input ‘HLP’ to know commands.
Enter command:
Enter Command: ITR
error=0
error=0
Enter Command: PMR
Pulse number? (-30000 to 30000)[0]: -281
Speed? (10 to 1500 pps) [10]: 444