Electrical Adjustments
SM3226-1 – 10FEB97
5–55
[4] Disconnect CN3 from the 5-PHASE PULSE MOTOR BOARD.
5-PHASE PULSE MOTOR BOARD
[5] Check that a JUMPER is installed from J1-2 to J1-3.
[6] Check that a JUMPER is installed from J2-2 to J2-3.
[7] Remove IC4.
[8] Connect the + side of the DIGITAL MULTIMETER, TL-3386, to CP2 (REF) and the COM side to CP1 (GND).
[9] Energize the LASER PRINTER.
[10] Use the PORTABLE COMPUTER to display the
CES Main Menu.
[11] Enter [1] for “Monitor Mode”.
[12] Enter [1] for motors.
MAIN MENU
1 Monitor Mode 4 System Params
2 System Logs 5 Debug Utility
3 Boards Diag 6 Exit
Enter Menu Item:
MONITOR MODE MENU
1 Motors 6 Seq Board Diag
2 Solenoids 7 Enter Commands
3 Relay 8 Set Beam-Splitter
4 Miscellaneous 9 Auto Sensor Test
5 Sensors 10 Semi-Auto Sensor Test
Enter Menu Item:
MOTOR DIAG MENU
1 Beam-splitter Pulse 6 Slow Scan
2 T-roller Pulse 7 Polygon
3 S-roller Pulse 8 S-mag
4 R-roller Pulse 9 R-mag
5 Film feeder Pulse 10 Fan
Enter menu item:
H129_1703BC
P129_1703BCA
CP1(GND)
CP2(REF)
R8
CN3
IC4
J2