Electrical Adjustments
SM3226-1 – 10FEB97
5–71
[10] Enter [7] for “Enter Commands”.
Note
• Commands must be entered using capital letters.
• See the Diagnostics section to clear any error
messages displayed on the PORTABLE
COMPUTER during this procedure.
[11] Enter [M] [G] [O] to open the SUPPLY
MAGAZINE WINDOW.
[12] Enter [I] [T] [R] to place the TRANSPORT
ROLLERS in the initial position.
[13] Enter [I] [F] [D] to move the SUCKER PADS into
the initial position.
[14] Enter [V] [P] [O] to start the
ELECTROMAGNETIC PUMP.
Note
The next 3 steps will move the SUPPLY ROLLER out
of the way.
[15] Enter [P] [M] [S].
[16] Enter [-] [5] [0] [0] for the pulse number.
[17] Enter [3] [0] [0] for the speed.
Input ‘HLP’ to know commands.
Enter command:
Enter Command: MGO
error=0
Enter Command: ITR
error=0
Enter Command: IFD
error=0
Enter Command:
Enter Command: VPO
error=0
error=0
Enter Command: PMS
Pulse number? (-30000 to 30000)[0]: -500
Speed? (10 to 1500 pps) [10]: 300