[23] Enter [P] [H] [T] to observe sensors.
Note
The state of CHS-1 displayed on the PORTABLE
COMPUTER should change between 0 and 1 during
the next step.
Important
Do not loosen FLAG SCREWS for the next step.
[24] Observe the state of CHS-1 displayed on the
PORTABLE COMPUTER while trying to move
the sensor flag without loosening the mounting
screws.
Important
If the state of CHS-1 changes from 0 to 1, the
adjustment is complete. Go to Step 33. If the state of
CHS-1 does not change, do the following step.
[25] Enter [P] [M] [F].
[26] Enter [-] [1] [0] for the pulse number.
[27] Enter [1] [0] for the speed.
[28] Enter [P] [H] [T] to observe sensors.
Enter Command: PHT
error=0
error=0
Enter Command: PMF
Pulse number? (-30000 to 30000)[0]: -10
Speed? (10 to 1500 pps) [10]: 10
Enter Command: PHT
error=0