Kingservo
86
Pr
Pr
Pr
Pr6B |
6B |
6B |
6B |
Set
Mechanic Brake Action Time as Server is ON
Initial Value
:
:
:
:
【
0
】
Setting Range
:
:
:
:
0~200
Unit
:
:
:
:ms
Function
:
:
:
:
As motor switch to Servo OFF, set time begins from Servo ON input signal
(SVO-ON
:
CN I/F PIN 29) is detected to be OFF(maintain brake) to brake release signal
(BK-OFF
:
CN I/F PIN 10,11) is OFF.
•Set for avoiding rotating motor to damage brake.
•While motor is rotating and Servo OFF, in right figure tb will be lower than setting time of
Pr6B or any time as rotary speed of motor is under 30r/min.
Pr
Pr
Pr
Pr6C |
6C |
6C |
6C |
Retrogradation Resistance Impressing Option
Initial Value
:
:
:
:
【
0
】
Setting Range
:
:
:
:
0~2
Unit
:
:
:
:–
–
–
–
Function
:
:
:
:
Directly use internal retrogradation resistance or chop away internal
retrogradation resistance and install retrogradation resistance in the exterior(P-B2 space of
connection terminal block) of driver to set this parameter.
Setting
Value
Used Retrogradation
Resistance
Retrogradation Resistance Overload Protection
0
Internal Resistance
Cooperate with internal resistance to make
retrogradation resistance overload protection act.
1
Impressing Resistance
Taking action limit of impressing resistance as 10%
DUTY, make it generate retrogradation resistance
overload protection
2
Impressing Resistance
No protection
Refer to sequence diagram of
Servo ON/OFF operaiton after
motor ceases.
Summary of Contents for KSDG Series
Page 4: ...KingServo 4...
Page 5: ...KingServo 5 Chapter One Identificaiotns of Products 1 1Safety Sign Warning Sign...
Page 10: ...KingServo 10 1 5 2 Motor KSMA 400W 750W 4...
Page 14: ...KingServo 14 RS 232 DC24V...
Page 24: ...KingServo 24 Speed Mode Speed Mode Speed Mode Speed Mode...
Page 26: ...KingServo 26 72 0 67 0 5 0 132 0 Kingservo L1 L2 L3 r t P B1 B2 U V W I F SIG MODE SET RS 232...
Page 88: ...Kingservo 88...
Page 104: ...KingServo 104...
Page 106: ...KingServo 106 Motor KSMA 400W 50h7 44 0 5 0 11 0...