Function of Flyback Resistor
·While load with large inertia reducing speed, flyback energy leads to rising of driver’s capacitor voltage,
so the flyback resistor is used to absorb and consume the excessive energy and protect driver.
·While using vertical ascending (Z axis) mechanism, flyback problem shall be payed attention to.
·specification of built-in flyback resistor: 150
Ω
and 50W.
■
Application of Built-in Flyback Resistor
·Keep short curicuit between B1 and B2.
·Set parameter Par 6C as 0 (default value is 0).
■
Application of External Flyback Resistor
·Connect P and B2 to external flyback resistor(150
Ω
).
· Set Parameter Par 6C as 1.
The power consumption of external resistor is limited to 10% duty, and set Par 6C as 2.
(while Par 6C is set as 2, overheating-protection fuse shall be installed, or else it may cause overheating
and burning-down of flyback resistor.).