Signal Name
Pin
Mark
Function
Position
command
pulse
inhibition
[input]
/
internal
speed setting
option two
33
PULS-IN
H /
INSP1
• Different functions as different control modes.
Position
control
• Command pusle input inhibition input(PULS-INH).
• If open with COM-, donot receive position pulse
command.
• This input can make Pr43(command pulse
inhibiton input invalidity) setting invalid.
Pr43
Content
0
Valid
1(Factory setting)
Invalid
Speed
control
• Select 1 input (INTSP1) for internal speed speed.
Torque
control
• The input is invalid.