Kingservo
50
Parameter
No.(Pr
□□
)
Function
Pre-set
Value
Range
Unit
Applicable
Mode
60
On-position range
10
0
~
32767
Pulse
P
61
Zero speed
50
10
~
10000
rpm
All
62
Speed attainment
1000
10
~
10000
rpm
S
,
T
63
Setting of excessive position deviation
20000
1
~
32000
Pulse
P
64
Invalid abnormality of excessive position
deviation
0
0
~
1
-
P
65
On-position output setting
0
0
~
3
-
P
66
State during drive inhibition input
0
0
~
1
-
All
68
Sequence control while alarm souds
0
0
~
3
-
All
69
Sequence control while server is closed
0
0
~
7
-
All
6A
Mechanical brake action setting while machine
ceases
0
0
~
200
ms
All
6B
Mechanical brake action setting while action
0
0
~
200
ms
All
★
★
★
★
6C
Retrogradation resistance impressing option
0
0
~
2
-
All
●
Modification of parameter No. marked with
★
★
★
★
will be effective only after control power is reset.