Kingservo
77
Pr
Pr
Pr
Pr58 |
58 |
58 |
58 |
Acceleration Time Setting
A
AA
A
Initial Value
:
:
:
:
【
0
】
Setting Range
:
:
:
:
0~10000
Unit
:
:
:
:1ms/ (1000rpm)
Function
:
:
:
:
In speed control mode, use speed intructions (speedup/speeddown) endowed
inside driver to make speed control.
As there is speed instruction of input step or internal speed setting is used, action of SOFT
START/SOFT DOWN can ge gained.
<
Attention
>
If connector use with position loop outside of driver, do not use speedup/speeddown
setting.
(
Set Pr58 and Pr59 to 0
)
Pr
Pr
Pr
Pr59 |
59 |
59 |
59 |
Speed-down Time Setting
A
AA
A
Initial Value
:
:
:
:
【
0
】
Setting Range
:
:
:
:
-
0~10000
Unit
:
:
:
:1ms/ (1000rpm)
Function
:
:
:
:
Refer to
Pr58
ta
Pr58 × 1ms/1000r/min
td
Pr59 × 1ms/1000r/min