Chapter 13 SPECIFICATIONS
(13) Power Consumption:
In calm wind
Maximum (Velocity of the wind: 100 kn)
JMA-3404
Approx. 60W
Approx. 60W
JMA-3406
Approx. 85W
Approx. 180W
JMA-3406HS
Approx. 85W
Approx. 230W
JMA-3411-4
Approx. 100W
Approx. 210W
JMA-3411-4HS Approx. 100W
Approx. 360W
JMA-3411-6
Approx. 100W
Approx. 210W
JMA-3411-6HS Approx. 100W
Approx. 360W
(14) Range of power supply voltage fluctuation
+10.8 to 31.2 VDC (Display Unit) (JMA-3404, JMA-3406)
* JMA-3404/JMA-3406 input voltage upper limit is +30%
of DC24V.
+21.6 to 31.2 VDC (Display Unit)
(JMA-3406HS, JMA-3411-4/4HS/6/6HS)
DC12/24V -10%/+30%
(15) Pre heat time
Approx. within 1min30sec.
(16) Display unit
Refer to Display unit Specifications
(17)Inter-unit Cables
Option
Length selectable (CFQ6912-5/10/15/20/30m)
When using JMA-3404 and JMA-3406 with 12V DC, the
maximum cable length is 20m or less.
Summary of Contents for JMA-3400 Series
Page 2: ......
Page 23: ...WARNING LABEL MOUNTING POINT xxi NKE 2103 4 4HS 6 6HS SCANNER UNIT NCD 2364 DISPLAY UNIT ...
Page 31: ...EQUIPMENT APPEARANCE xxix NKE 2043 SCANNER UNIT NKE 2063A AHS SCANNER UNIT ...
Page 32: ...EQUIPMENT APPEARANCE xxx NKE 2103 4 4HS 6 6HS SCANNER UNIT ...
Page 34: ...EQUIPMENT APPEARANCE xxxii Fuse ...
Page 48: ......
Page 51: ...Chapter 1 INSTALLATION 3 1 2 3 DIMENSIONAL DRAWING OF DISPLAY MOUNTING ...
Page 56: ...Chapter 1 INSTALLATION 8 FLUSH MOUNTING TEMPLATE Note Please note the paper size ...
Page 85: ...Chapter 2 THE BASIC OPERATION 37 2 2 OPERATION UNIT ࢫࣆ ձ ղ ճ մ յ ն շ ո չ պ վ տ ւ ջ ռ ս ր ց ...
Page 266: ...Chapter 13 SPECIFICATIONS 218 13 1 SCANNER DIMENSION 13 1 1 NKE 2043 ...
Page 270: ...Chapter 13 SPECIFICATIONS 222 13 2 DISPLAY DIMENSION 13 2 1 NCD 2364 ...
Page 283: ...235 Chapter 13 SPECIFICATIONS MEMO ...
Page 293: ...APPENDIX A 10 MEMO ...
Page 313: ......