Chapter 4
DS1 Test Commands
Description of DS1 test commands
CT-650 Command-Line Reference Guide
Release 9.4
49
Example
The following command enables logging of test results for bit error
seconds and frame error seconds, but not severely errored seconds.
Log_Errors y n y n
Remarks
– Use the
Examine_Log
command to review the logged results.
– The logged errors are in addition to logged results displayed by
the
Information Configure Miscellaneous
command
(see
– Use the
Information Configure Default DS1
command to
verify the default settings for logging errors.
Monitor
Starts a new test and allocates a new RTU to monitor a DS1 signal.
Syntax
Monitor <
> <
<
<
>
Monitors a DS1 signal from a 3/1 or 1/0 DCS that has been configured
for either a single- or dual-FAD test connection.
Monitor <
>
<
>
Monitors a DS1 signal from a DSX or direct connection source.
Remarks
– If any framing other than SLC is chosen, the CT-650 tries to allo-
cate DT1 cards first, then DTU cards.
– If a dual-FAD connection is requested, the CT-650 allocates both
test card RTUs.
– If a single-FAD connection is requested, the CT-650 allocates an
available RTU. If you have another single-FAD test running, the
CT-650 attempts to allocate the other RTU on the same test card
before allocating additional RTUs.
Summary of Contents for CT-650
Page 1: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Page 2: ......
Page 3: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Page 4: ......
Page 22: ...Contents xxii CT 650 Command Line Reference Guide Release 9 4 ...
Page 240: ...Appendix D Customer Services and Support Training options 214 CT 650 User s Guide Release 9 3 ...
Page 247: ......