Chapter 2
Auxiliary and Common Commands
Auxiliary commands
32
CT-650 Command-Line Reference Guide
Release 9.4
Example
The following command defines a loop-up code of 1001 and a loop-
down code of 1000.
Prog_Loop 1001 1000
Record
Starts or stops recording commands to a log file.
Syntax
Record On <
Record Off
Remarks
– You can edit a log file with the UNIX vi text editor.
– When you type
Record Off
, the CT-650 asks if you want to save
a copy of the batch file in the common system directory. This
allows any user to execute the batch file.
– If you record to an existing file, the CT-650 appends the subse-
quent commands to those already saved in the file.
Example
The following procedure records a command sequence into a batch
file named
mon33
.
1
Type
Record On mon33
.
The following message appears:
Keyboard recording is
ON. Commands are recorded to file mon33.
2
Press any key to return to the Main Menu.
3
Type a command to be recorded.
4
Type
Record Off
, and press
Enter
.
5
At the prompt, press
Y
to save the batch file in a common direc-
tory.
6
Press any key to return to the Main Menu.
The message appears
Keyboard recording is OFF
.
Summary of Contents for CT-650
Page 1: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Page 2: ......
Page 3: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Page 4: ......
Page 22: ...Contents xxii CT 650 Command Line Reference Guide Release 9 4 ...
Page 240: ...Appendix D Customer Services and Support Training options 214 CT 650 User s Guide Release 9 3 ...
Page 247: ......