Appendix A
Test Results Definitions
Information results
CT-650 Command-Line Reference Guide
Release 9.4
107
Test Port
Port used for the test.
N/A
appears when an RTU port
is idle.
Framing
or
FRM
Default framing mode for the idle condition when the
RTU is not in use.
Tx Level
Transmitted signal level.
Timing
Source
Timing source for the current test. If the RTU does not
follow the timing source selected in the RTU configu-
ration, the field appears as white text on black back-
ground. Possible values are as follows:
–
INTERNAL
Internal timing selected.
–
EXTERNAL
External timing selected.
–
RECOVERED
or
REC
Recovered timing selected, or
split is set for local loopback.
Idle Cond
Pattern transmitted when the RTU is not in use. Possi-
ble values are as follows:
–
111 (All Ones)
DCS keepalive pattern is trans-
mitted with the default framing.
–
x1C (Hexadecimal)
x1C pattern is transmitted.
–
LLB (Local Loopback)
Regenerated receive
signal is transmitted through the RTU.
–
1100 (IDLE)
Transmits a DCS keep-alive pat-
tern with the default framing.
–
THRU
Retransmits received data to the transmit
lines.
Field
Description