Chapter 5
FT1 Test Commands
Description of FT1 test commands
CT-650 Command-Line Reference Guide
Release 9.4
55
FT1_Measure
Executes an intrusive test on the chosen side of the FT1 FAD being
tested.
Syntax
FT1_Measure <
> <
<
> <
>
Remarks
– This command is available only after executing an
FT1_Split
.
– Not all
test_pattern_types
require a
test_pattern
param-
eter.
FT1_Split
Establishes an EF split between the monitored digroup and a DTU.
Syntax
FT1_Split <
Remark
This command is available only after executing a
Monitor
command.
Log_Errors
Starts logging of errors detected during a test.
Syntax
Log_Errors <
>
Example
The following command enables logging of test results for bit error
seconds and severe bit error seconds.
Log_Errors y y
Remarks
– To review the logged results, use the
Examine_Log
command.
– The logged errors are in addition to logged results displayed by
the
Information Configure Miscellaneous
command
(see
– To verify the default settings for logging errors, use the
Informa-
tion Configure Default DS1/FT1
command.