Appendix B
Command Parameter Definitions
Parameter listing
CT-650 Command-Line Reference Guide
Release 9.4
181
Answer or dial using one of the following seizure types. For an
explanation of VF channel seizure, see
.
–
Delay_Dial
A Delay Dial seizure sequence. The originating
end delays 300 ms to allow the called office to return an off-
hook indication. Outpulsing is enabled 70 ms after off-hook
received. Trunk type is STD E&M.
–
FXO_Ground
A Foreign Exchange Office seizure sequence.
Trunk type is Ground Start.
–
FXS_Ground
A Foreign Exchange Station seizure sequence.
Trunk type is Ground Start.
–
FXO_Loop
A Foreign Exchange Office seizure. Trunk type is
Loop Start.
–
FXS_Loop
A Foreign Exchange Station seizure. Trunk type is
Loop Start.
–
Immediate Dial
An Immediate Dial seizure.
–
SLC_Gnd_Office
An SLC Ground Start Office.
–
SLC_Gnd_Station
An SLC Ground Start Station.
–
SLC_Lp_Office
An SLC Loop Start Office.
–
SLC_Lp_Station
An SLC Loop Start Station.
–
Wink_Start
A wink-start seizure sequence. Trunk type is STD
E&M.
–
UserDefinedTrunk
User-defined seizure type.
Additional parameter required for some seizure types:
–
delay_duration
Applies to Delay Dial. The delay duration
time, in milliseconds, ranging from 30 to 1600.
–
wink_duration_time
Applies to Wink Duration. The wink
duration time in milliseconds, ranging from 30 to 600.
Shelf location or address of the RTU in the system. This parameter
is always 1 for the 650 and the 650-S.
The side of the RTU being tested. Possible values are
A
and
B
.
Table 8
Command-line parameter definitions (Continued)
Parameter
Definition
Summary of Contents for CT-650
Page 1: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Page 2: ......
Page 3: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Page 4: ......
Page 22: ...Contents xxii CT 650 Command Line Reference Guide Release 9 4 ...
Page 240: ...Appendix D Customer Services and Support Training options 214 CT 650 User s Guide Release 9 3 ...
Page 247: ......