Appendix A
Test Results Definitions
DS0 DDS results
CT-650 Command-Line Reference Guide
Release 9.4
159
Receive
Byte/Code
Channel binary byte and signaling code status for a 56
kB channel. For 64 kB clear channel testing, the dis-
played value has no meaning. These codes and bytes
may appear on the screen. An
X
indicates a “do not
care” bit.
Data Count
Number of bytes received that do not contain control
codes.
Acknowledge
Number of acknowledge codes detected since the test
started.
Block
Number of block codes (S0001010) detected since the
test started.
Far End
Voice
Number of Far End Voice codes (S1011010) detected
since the test started.
LoopBack
Enable
Number of loopback enable codes (S1010110)
detected since the test started.
MJU Alert
Number of MJU alert codes (S1110010) detected
since the test started.
Release
Number of release codes (S1111000) detected since
the test started.
Test Alert
Number of test alert codes (S1101100) detected since
the test started.
Test
Test name.
N/A
appears for selftests.
Undefined
Control
Codes
Number of undefined control codes detected since the
test started.
Field
Description
Summary of Contents for CT-650
Page 1: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Page 2: ......
Page 3: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Page 4: ......
Page 22: ...Contents xxii CT 650 Command Line Reference Guide Release 9 4 ...
Page 240: ...Appendix D Customer Services and Support Training options 214 CT 650 User s Guide Release 9 3 ...
Page 247: ......