Appendix A
Test Results Definitions
DS3 results
CT-650 Command-Line Reference Guide
Release 9.4
123
RX FRM
Type of framing detected by the receiver. If the
detected framing does not match the selected framing,
this field appears as white text on a black background.
Possible framing formats include:
–
C-bit
DS3 C-bit framed signal detected.
–
M13
DS3 M13 framed signal detected.
–
N/A
No signal is detected.
–
UNFRAMED
Unframed DS3 signal detected.
TIM SRC
Timing source for the current test. If the RTU does not
follow the timing source selected in the RTU configu-
ration, the field appears as white text on black back-
ground. Possible values are as follows:
–
INTERNAL
Internal timing selected.
–
EXTERNAL
External timing selected.
–
RECOVERED
or
REC
Recovered timing selected, or
split is set for local loopback.
Field
Description