Appendix A
Test Results Definitions
FT1 results
CT-650 Command-Line Reference Guide
Release 9.4
145
FT1 results
The following sections describe the fields appearing under various
FT1 test results screens.
Header
The following fields appear in the header of the FT1 test results
screens.
Test Length
Length of test for a timed test, in hours and minutes.
Field
Description
Field
Description
Test
Test name.
N/A
appears for selftests.
DG
Digroup being tested.
UNKNOWN
appears if the digroup
cannot be identified.
N/A
appears for a selftest.
SIG SRC
Signal source for the tested circuit. Possible values
are as follows:
–
INT
or
INTERNAL
indicates the signal comes from
the backplane from another card.
–
EXT
or
EXTERNAL
indicates the signal comes from
the DCS or a direct connection.
–
M13
or
EXTERNAL (M13 MUX)
indicates the sig-
nal comes from the DS3 Demux/Shelf Controller
Card or from an M13 card configured for the
CT-650.
–
RCVD T3
is the only source that indicates the DS3
signal is not being dropped from a higher rate.
During a selftest, the
RCVD T3
signal is an inter-
nally generated DS3 signal from the RTU.
Summary of Contents for CT-650
Page 1: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Page 2: ......
Page 3: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Page 4: ......
Page 22: ...Contents xxii CT 650 Command Line Reference Guide Release 9 4 ...
Page 240: ...Appendix D Customer Services and Support Training options 214 CT 650 User s Guide Release 9 3 ...
Page 247: ......