IDT Configuration Registers
PES24N3A User Manual
9 - 62
April 10, 2008
Notes
SWPERCTL - Switch Parity Error Reporting Control (0x748)
SWPECNT - Switch Parity Error Count (0x74C)
SWTOCTL - Switch Time-Out Control (0x750)
SWTOSTS - Switch Time-Out Status (0x754)
Bit
Field
Field
Name
Type
Default
Value
Description
1:0
EEPE
RW
0x2
End-to-End Parity Error Reporting.
This field controls the
manner in which end-to-end parity errors detected at this
port are reported. An end-to-end parity error is reported as
specified in this field whenever the EEPE bit in the Switch
Parity Error Status (SWPESTS) register transitions from a
zero to a one.
0x0 - (none) The end-to-end parity error is not reported
0x1 - (correctable) The port generates an ERR_COR mes-
sage to the root.
0x2 - (nonfatal) The port generates an ERR_NONFATAL
message to the root.
0x3 - (fatal) The port generates an ERR_FATAL message to
the root.
31:2
Reserved
RO
0x0
Reserved field.
Bit
Field
Field
Name
Type
Default
Value
Description
7:0
EEPEC
RCW
0x0
Sticky
End-to-End Parity Error Count.
This field is incremented
each time an end-to-end parity error is detected at the port
until it saturates at its maximum count value (i.e., it does not
roll over from 0xFF to 0x00).
This counter saturates at its maximum value.
Reading this field causes it to be cleared.
31:8
Reserved
RO
0x0
Reserved field.
Bit
Field
Field
Name
Type
Default
Value
Description
0
ETO
RW
0x1
Sticky
Enable Switch Time-outs.
When this bit is set, switch time-
outs for this port are enabled. In this mode, a TLP will be
discarded if it has been in this port’s input queue for more
than the specified switch core time-out limit. See section
Switch Time-Outs on page 3-16 for more information.
31:1
Reserved
RO
0x0
Reserved field.
Bit
Field
Field
Name
Type
Default
Value
Description
0
PTLPTO
RW1C
0x0
Posted TLP Time-Out.
This bit is set when a TLP is dis-
carded from the port’s IFB posted queue because of a time-
out.
1
NPTLPTO
RW1C
0x0
Non-Posted TLP Time-Out.
This bit is set when a TLP is
discarded from the port’s IFB non-posted queue because of
a time-out.
Summary of Contents for 89HPES24N3A
Page 10: ...IDT Table of Contents PES24N3A User Manual iv April 10 2008 Notes...
Page 12: ...IDT List of Tables PES24N3A User Manual vi April 10 2008 Notes...
Page 14: ...IDT List of Figures PES24N3A User Manual viii April 10 2008 Notes...
Page 18: ...IDT Register List PES24N3A User Manual xii April 10 2008 Notes...
Page 64: ...IDT Link Operation PES24N3A User Manual 4 8 April 10 2008 Notes...
Page 88: ...IDT Power Management PES24N3A User Manual 7 4 April 10 2008 Notes...
Page 160: ...IDT Configuration Registers PES24N3A User Manual 9 66 April 10 2008 Notes...