IDT Configuration Registers
PES24N3A User Manual
9 - 37
April 10, 2008
Notes
ECFGDATA - Extended Configuration Space Access Data (0x0FC)
Advanced Error Reporting (AER) Enhanced Capability
AERCAP - AER Capabilities (0x100)
AERUES - AER Uncorrectable Error Status (0x104)
Bit
Field
Field
Name
Type
Default
Value
Description
31:0
DATA
RW
0x0
Configuration Data.
A read from this field will return the
configuration space register value pointed to by the ECF-
GADDR register. A write to this field will update the contents
of the configuration space register pointed to by the ECF-
GADDR register with the value written. For both reads and
writes, the byte enables correspond to those used to access
this field.
When the ECFGADDR register points to the ECFGDATA
register, then reads from ECFGDATA return zero and writes
are ignored. When the ECFGADDR register points to itself,
writes to the ECFGDATA register modify the contents of the
ECFGADDR register.
SMBus reads of this field return a value of zero and SMBus
writes have no effect.
Bit
Field
Field
Name
Type
Default
Value
Description
15:0
CAPID
RO
0x1
Capability ID.
The value of 0x1 indicates an advanced error
reporting capability structure.
19:16
CAPVER
RO
0x1
Capability Version.
The value of 0x1. indicates compatibil-
ity with version 1 of the specification.
31:20
NXTPTR
RWL
0x200
Next Pointer.
Bit
Field
Field
Name
Type
Default
Value
Description
0
UDEF
RW1C
0x0
Sticky
Undefined.
This bit is no longer used in this version of the
specification.
3:1
Reserved
RO
0x0
Reserved field.
4
DLPERR
RW1C
0x0
Sticky
Data Link Protocol Error Status.
This bit is set when a
data link layer protocol error is detected.
5
SDOENERR RW1C
0x0
Sticky
Surprise Down Error Status.
This bit is set when a sur-
prise down error is detected.
This bit is always zero if the SDERR bit in the PCIELCAP
register is not set.
11:6
Reserved
RO
0x0
Sticky
Reserved field.
12
POISONED
RW1C
0x0
Sticky
Poisoned TLP Status.
This bit is set when a poisoned TLP
is detected.
13
FCPERR
RW1C
0x0
Sticky
Flow Control Protocol Error Status.
This bit is set when a
flow control protocol error is detected.
Summary of Contents for 89HPES24N3A
Page 10: ...IDT Table of Contents PES24N3A User Manual iv April 10 2008 Notes...
Page 12: ...IDT List of Tables PES24N3A User Manual vi April 10 2008 Notes...
Page 14: ...IDT List of Figures PES24N3A User Manual viii April 10 2008 Notes...
Page 18: ...IDT Register List PES24N3A User Manual xii April 10 2008 Notes...
Page 64: ...IDT Link Operation PES24N3A User Manual 4 8 April 10 2008 Notes...
Page 88: ...IDT Power Management PES24N3A User Manual 7 4 April 10 2008 Notes...
Page 160: ...IDT Configuration Registers PES24N3A User Manual 9 66 April 10 2008 Notes...