background image

Can be integrated
with ZM ejector system.

Variable hysteresis

1 to 10% of set pressure (Variable)

Easy and simple wiring

Connector type

Series

 ZSE1

 (For Vacuum)

/ISE1

 (For Positive Pressure)

Compact Pressure Switch

For General Pneumatics

RoHS

846

Summary of Contents for ZSE1 Series

Page 1: ...with ZM ejector system Variable hysteresis 1 to 10 of set pressure Variable Easy and simple wiring Connector type Series ZSE1 For Vacuum ISE1 For Positive Pressure Compact Pressure Switch For General Pneumatics RoHS 846 ...

Page 2: ...h Nil 30 50 0 6 m 3 m 5 m Note 1 M5 x 0 8 female threaded Note 2 Single mounting style M5 x 0 8 female threaded Positive pressure Vacuum NPN open collector 1 output w o analog output 3 turns adjustment NPN open collector 1 output w o analog output 200 degrees adjustment NPN open collector 2 output w o analog output 3 turns adjustment NPN open collector 2 output w o analog output 200 degrees adjust...

Page 3: ...60 C With no condensation and no freezing Operating Stored 35 to 85 RH With no condensation 3 F S or less 1000 VAC for 1 min between terminals and housing 50 MΩ or more 500 VDC measured via megohmmeter between terminals and housing 01 R 8 M5 x 0 8 T1 NPTF 1 8 M5 x 0 8 00 ZM ejector mount type 40 g Including 0 6 m Long lead wire Heat resistant vinyl electric wire 4 wire Conductor area 0 3 mm2 Insul...

Page 4: ... of the output signal The set pressure is the pres sure selected to switch from OFF to ON condition Set point Atmospheric pressure 0 High vaccum Hysteresis High pressure How to Use Connector 1 Attaching and detaching connectors When assembling the connector to the switch housing push the connector straight onto the pins until the lever locks into the housing slot When removing the connector from t...

Page 5: ...rown DC Black OUT1 White OUT2 Blue DC Load Main circuit Main circuit Main circuit Main circuit Compact Pressure Switch Series ZSE1 ISE1 Internal Circuits and Wiring Examples 14 15 NPN 1 output 16 17 NPN 2 outputs 18 19 NPN 1 output Analog voltage output 55 PNP 1 output 849 1 ZSE30 ISE30 ZSE40 ISE40 ZSE10 ISE10 ISE70 ZSE80 ISE80 ZSE ISE ZSP PS ISA2 PSE IS ISG ZSM1 ZSE ISE A ...

Page 6: ...setting trimmer Pressure setting trimmer 2 Pressure setting trimmer 1 Indicator light Red Green Pressure supply port ø2 O ring 2 x M2 5 x 24L Mounting threads Pressure supply port ø2 O ring 2 x M2 5 x 24L Mounting threads Connector type SE1 14C 15C 18C 19C I Z I Z Grommet type SE1 14 15 18 19 01 T1 01 T1 SE1 01 16C 17C SE1 01 16 17 I Z I Z Pressure setting trimmer Indicator light Red Hysteresis se...

Reviews: