Command
Shows a list of command data. Double clicking the line displays the Data Settings dialog box.
For details, refer to “Data Settings Dialog Box” on page 22-36. The maximum amount that can be configured is 32
commands per protocol.
The content displayed in lists varies based on the type of command.
Constant (Character):
Displays the specified data enclosed in " ".
"Data"
Example: "1234"
Constant (Hexadecimal): Displays the specified data with each byte value enclosed in ' '.
'Data of the first byte' 'Data of the second byte' 'Data of the third byte' 'Data of the
forth byte'
Example: '31' '32' '33' '34'
Device:
Displays the specified data enclosed by < >, in the following order.
<Device Conversion Type Number of bytes Variable Words Storage Method of data>
Device:
Displays the device address enclosed by [ ]
When the
Use Reference Device
check box is selected,
displays as OFFSET([Device], [Reference Device])
Number of bytes:
Displays the number of bytes of the transmitted or
received data.
Conversion Type:
Display the conversion methods for values of devices as
follows.
B16-A: When
Binary (HEX)
to
ASCII
is selected
B10-A: When
Binary (DEC)
to
ASCII
is selected
N: When
No Conversion
is selected
Variable:
When the
Variable
check box is selected, variables are
displayed as follows.
V00: When
NULL (00h)
is selected for transmission
command
V [Device]: When
Device
is selected for transmission
command
V: In the case of receive command
Words:
Displays the number of word devices for transmitting or
receiving data.
Storage Method of data: Displays the handling method for value of read device as
follows.
U: When
from Upper byte
is selected
L: When
from Lower byte
is selected
Example: <OFFSET([LDR0100], [LDR0300]) N 2V[LDR0200] 2 U>
Registering Constant (Character):
Displays the specified data enclosed in << >>.
<<Index No. of No. 1: Data of No. 1 Index No. of No. 2: Data of No. 2 ... Index No. of
No. N: Data of No. N Index Device>> (N = 1 to 100)
Data:
Displays the data enclosed by " "
Index Device:
Displays the device address enclosed by [ ]
Example: <<1:"123" 2 :"456" 3 :"789" [LDR0100]>>
Registering Constant (Hexadecimal):
Displays the specified data enclosed in << >>.
<<Index No. of No. 1: Data of No. 1 Index No. of No. 2: Data of No. 2 ... Index No. of
No. N: Data of No. N Index Device>> (N = 1 to 100)
Data:
Displays the data enclosed by ' '
Index Device:
Displays the device address enclosed by [ ]
Example: <<1:'313233' 2:'343536' 3 :'373839' [LDR0100]>>
Summary of Contents for SmartAXIS Touch FT1A Series
Page 1: ...FT1A Series FT9Y B1390 4 SmartAXIS Touch User s Manual ...
Page 22: ...Contents Preface 21 SmartAXIS Touch User s Manual ...
Page 240: ...6 Using Library Screens 4 36 SmartAXIS Touch User s Manual ...
Page 416: ...2 Multi State Lamps 8 26 SmartAXIS Touch User s Manual ...
Page 558: ...9 Calendar 9 142 SmartAXIS Touch User s Manual ...
Page 668: ...6 Timer 11 52 SmartAXIS Touch User s Manual ...
Page 754: ...4 Using Data and Detected Alarms 13 34 SmartAXIS Touch User s Manual ...
Page 792: ...4 Using the Data 14 38 SmartAXIS Touch User s Manual ...
Page 810: ...4 Using the Data 15 18 SmartAXIS Touch User s Manual ...
Page 870: ...3 Text Manager 19 16 SmartAXIS Touch User s Manual ...
Page 924: ...6 Important Notes 20 54 SmartAXIS Touch User s Manual ...
Page 1036: ...5 User Communication 22 74 SmartAXIS Touch User s Manual ...
Page 1092: ...2 Monitoring on the Touch 24 26 SmartAXIS Touch User s Manual ...
Page 1142: ...2 Word Devices 27 18 SmartAXIS Touch User s Manual ...
Page 1186: ...2 Analog Cartridge 29 34 SmartAXIS Touch User s Manual ...
Page 1194: ...3 Handling Problems 30 8 SmartAXIS Touch User s Manual ...