7 Alarm Log Display
9-108
SmartAXIS Touch User’s Manual
■
Selects the specification method for line spacing in the list and configures the line spacing.
*1 Advanced mode only
Set with Number of Lines:
Specifies the number of lines for the message to display for one alarm line.
Number of Lines:
Enter the number of lines (1 to 10). To completely display a message that
contains newlines, a number of lines that is equal to or greater than the number
of message lines is required.
When you enter a value in
Number of Lines
,
Height (dots)
is automatically calculated according
to the display area.
The relationship between the number of lines and the height (dots) is height (dots) = number of
lines x magnification H x 16.
Number of Lines Magnification H
Height
1
1
×
× 16 = 16 dots
Current fault
Current fault
has occurred
Pump fault
Pump fault
has occurred
2
1
×
× 16 =
Current fault
has occurred
Pump fault
has occurred
3
1
×
× 16 =
Current fault
has occurred
has occurred
Pump fault
3
2
×
× 16 =
Number of Lines Magnification H
Height
Number of Lines Magnification H
Height
32 dots
48 dots
Number of Lines Magnification H
Height
96 dots
When the message is 2 lines,
2nd line is not shown.
Since the alarm line spacing is adjusted with the number of lines for the message fixed, this option is
convenient to use when displaying multi-line messages.
Set with Dots: Specifies the line spacing for the message to display for one alarm line in dots.
Height (dots):
Enter the height (8 to 160). To completely display a message, a height equal to
or greater than
Magnification H
x 16 dots x the number of message lines is
required.
When
Magnification H
is 1
To display a one-line message, 1 x 16 = 16 dots, a height of 16 dots or higher is required.
To display a two-line message, 2 x 16 = 32 dots, a height of 32 dots or higher is required.
When
Magnification H
is 2
To display a one-line message, 1 x 32 = 32 dots, a height of 32 dots or higher is required.
To display a two-line message, 2 x 32 = 64 dots, a height of 64 dots or higher is required.
16 dots
Height
Current fault has occurred
Pump fault has occurred
Height
Height
16 dots
32 dots
Current fault
has occurred
has occurred
Pump fault
Current fault
Pump fault
When the message is two lines,
The second line is not shown.
Height
32 dots
Current fault has occurred
Pump fault has occurred
Height
32 dots
Current fault
Current fault
Pump fault
Pump fault
Height
64 dots
has occurred
has occurred
When the message is two lines,
The second line is not shown.
Since only one line of the title is displayed, the title line spacing = 1 (number of lines) x
Magnification H
x 16, regardless of the
Line Spacing
setting.
Example: When
Magnification H
is 1, the title line spacing = 1 x 1 x 16 = 16 dots
When
Magnification H
is 2, the title line spacing = 1 x 2 x 16 = 32 dots
Summary of Contents for SmartAXIS Touch FT1A Series
Page 1: ...FT1A Series FT9Y B1390 4 SmartAXIS Touch User s Manual ...
Page 22: ...Contents Preface 21 SmartAXIS Touch User s Manual ...
Page 240: ...6 Using Library Screens 4 36 SmartAXIS Touch User s Manual ...
Page 416: ...2 Multi State Lamps 8 26 SmartAXIS Touch User s Manual ...
Page 558: ...9 Calendar 9 142 SmartAXIS Touch User s Manual ...
Page 668: ...6 Timer 11 52 SmartAXIS Touch User s Manual ...
Page 754: ...4 Using Data and Detected Alarms 13 34 SmartAXIS Touch User s Manual ...
Page 792: ...4 Using the Data 14 38 SmartAXIS Touch User s Manual ...
Page 810: ...4 Using the Data 15 18 SmartAXIS Touch User s Manual ...
Page 870: ...3 Text Manager 19 16 SmartAXIS Touch User s Manual ...
Page 924: ...6 Important Notes 20 54 SmartAXIS Touch User s Manual ...
Page 1036: ...5 User Communication 22 74 SmartAXIS Touch User s Manual ...
Page 1092: ...2 Monitoring on the Touch 24 26 SmartAXIS Touch User s Manual ...
Page 1142: ...2 Word Devices 27 18 SmartAXIS Touch User s Manual ...
Page 1186: ...2 Analog Cartridge 29 34 SmartAXIS Touch User s Manual ...
Page 1194: ...3 Handling Problems 30 8 SmartAXIS Touch User s Manual ...