4 Special Functions
3-54
SmartAXIS Touch User's Manual
●
Designation
The settings and actions for each control device are as follows.
■
Internal Relay (M)
• The default setting is
Clear All
.
■
Shift Register (R)
• The default setting is
Clear All
.
■
Counter (C)
• The default setting is
Keep All
.
■
Data Register (D)
• The default setting is
Keep All
.
Configuration
Operation
Clear All
All internal relays are cleared when the Touch starts operation.
Keep All
The states of all internal relays are retained while the Touch is powered OFF.
Keep Specified Range
The states of all internal relays are retained while the Touch is powered OFF.
Internal relays outside the specified range are cleared when operation starts.
Configuration
Operation
Clear All
All shift registers are cleared when the Touch starts operation.
Keep All
The states of all shift registers are retained while the Touch is powered OFF.
Keep Specified Range
The states of all shift registers are retained while the Touch is powered OFF.
Shift registers outside the specified range are cleared when operation starts.
Configuration
Operation
Keep All
Counter current values are retained when the Touch is powered OFF.
Clear All
All counter current values are cleared when the Touch starts operation.
Clear Specified Range
Only counter current values within the specified range are cleared when the Touch
starts operation. Counter current values outside the specified range are retained.
Configuration
Operation
Keep All
Data register values are retained when the Touch is powered OFF.
Clear All
All data register values are cleared when the Touch starts operation.
Clear Specified Range
Only data register values within the specified range are cleared when the Touch starts
operation. Data register values outside the specified range are retained.
• Relays and registers specified under
Clear All
or
Clear Specified Range
are cleared when the Touch
starts operation. Values in the powered OFF state are retained until power is turned on and operation
starts.
• It is not possible to configure keep/clear settings for special data registers. This action is equivalent to
that of
Keep All
.
• It is not possible to configure keep/clear settings for special internal relays. For details about actions when
power is cut or operation is stopped, refer to Chapter 27 “Special Internal Relay (M)” on page 27-5
Summary of Contents for SmartAXIS Touch FT1A Series
Page 1: ...FT1A Series FT9Y B1390 4 SmartAXIS Touch User s Manual ...
Page 22: ...Contents Preface 21 SmartAXIS Touch User s Manual ...
Page 240: ...6 Using Library Screens 4 36 SmartAXIS Touch User s Manual ...
Page 416: ...2 Multi State Lamps 8 26 SmartAXIS Touch User s Manual ...
Page 558: ...9 Calendar 9 142 SmartAXIS Touch User s Manual ...
Page 668: ...6 Timer 11 52 SmartAXIS Touch User s Manual ...
Page 754: ...4 Using Data and Detected Alarms 13 34 SmartAXIS Touch User s Manual ...
Page 792: ...4 Using the Data 14 38 SmartAXIS Touch User s Manual ...
Page 810: ...4 Using the Data 15 18 SmartAXIS Touch User s Manual ...
Page 870: ...3 Text Manager 19 16 SmartAXIS Touch User s Manual ...
Page 924: ...6 Important Notes 20 54 SmartAXIS Touch User s Manual ...
Page 1036: ...5 User Communication 22 74 SmartAXIS Touch User s Manual ...
Page 1092: ...2 Monitoring on the Touch 24 26 SmartAXIS Touch User s Manual ...
Page 1142: ...2 Word Devices 27 18 SmartAXIS Touch User s Manual ...
Page 1186: ...2 Analog Cartridge 29 34 SmartAXIS Touch User s Manual ...
Page 1194: ...3 Handling Problems 30 8 SmartAXIS Touch User s Manual ...