oject
■
Ignore communication errors and continue operation
Select this check box to continue Touch operation even when a communication error occurs.
This option is only displayed when the communication driver
Connection
is
1:N Communication
.
Display error message:
Select this check box to display an error message (communication error) when a
communication error occurs and operation continues.
Ack
is displayed on the error
message (communication error).
When the
Ignore communication errors and continue operation
check box is
cleared,
Ack
is not displayed on the error message.
Auto retry:
Select this check box to automatically retry communication from the Touch to the station
number where the communication error occurred when a communication error occurs
and operation continues.
All other communication stops while retrying.
To manually retry communication, clear the
Auto retry
check box.
To retry all station numbers, write 1 in bit 1 (initialize) of the device address configured by
Batch
monitoring the communication error information for all Station Numbers
.
To individually retry communication, write 1 in bit 0 (connection setting) of the device address configured by
Monitoring communication error information for each station number, individually
.
Batch monitoring the communication error information for all Station Numbers:
Specifies the device that stores communication error information for all station numbers.
Only the HMI devices can be configured for this option.
Click
to display the Device Address Settings dialog box. For the device address
configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-62.
The information stored as error information is as follows. For details, refer to the
"External Device Setup Manual".
• Initialization
• Conditions under which the error occurred
• Read error log
• Write error log
Monitoring communication error information for each station number, individually:
Specifies the device that stores communication error information for each station
number. Only the HMI devices can be configured for this option.
Click
to display the Device Address Settings dialog box. For the device address
configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-62.
This error information utilizes a maximum of 256 devices. Use caution so that the used
addresses do not overlap with other addresses.
The information stored as error information is as follows. For details, refer to the
"External Device Setup Manual".
• Connection settings
• Conditions under which the error occurred
• Read error log
• Write error log
Summary of Contents for SmartAXIS Touch FT1A Series
Page 1: ...FT1A Series FT9Y B1390 4 SmartAXIS Touch User s Manual ...
Page 22: ...Contents Preface 21 SmartAXIS Touch User s Manual ...
Page 240: ...6 Using Library Screens 4 36 SmartAXIS Touch User s Manual ...
Page 416: ...2 Multi State Lamps 8 26 SmartAXIS Touch User s Manual ...
Page 558: ...9 Calendar 9 142 SmartAXIS Touch User s Manual ...
Page 668: ...6 Timer 11 52 SmartAXIS Touch User s Manual ...
Page 754: ...4 Using Data and Detected Alarms 13 34 SmartAXIS Touch User s Manual ...
Page 792: ...4 Using the Data 14 38 SmartAXIS Touch User s Manual ...
Page 810: ...4 Using the Data 15 18 SmartAXIS Touch User s Manual ...
Page 870: ...3 Text Manager 19 16 SmartAXIS Touch User s Manual ...
Page 924: ...6 Important Notes 20 54 SmartAXIS Touch User s Manual ...
Page 1036: ...5 User Communication 22 74 SmartAXIS Touch User s Manual ...
Page 1092: ...2 Monitoring on the Touch 24 26 SmartAXIS Touch User s Manual ...
Page 1142: ...2 Word Devices 27 18 SmartAXIS Touch User s Manual ...
Page 1186: ...2 Analog Cartridge 29 34 SmartAXIS Touch User s Manual ...
Page 1194: ...3 Handling Problems 30 8 SmartAXIS Touch User s Manual ...