1 Numerical Input
9-4
SmartAXIS Touch User’s Manual
■
Display Type
Selects the display type for the value as
Decimal
or
Hexadecimal
.
■
Data Format
Data Type:
Selects the type of data for the value.
The data type that can be configured differs according to
Display Type
. For the data
types that can be configured, see the table for
Digits
.
For details, refer to Chapter 2 “1.2 Available Data” on page 2-2.
Digits:
Specifies the digits to display. The range of digits that can be set varies based on the
display type and data type. The digits that can be set are as follows.
Display Type
Data Type
Digits
Decimal display
BIN16 (+), BIN16 (+/-)
1 to 5
BIN32 (+), BIN32 (+/-)
1 to 10
BCD4
1 to 4
BCD8
1 to 8
float32
1 to 10
Hexadecimal
display
BIN16 (+)
1 to 4
BIN32 (+)
1 to 8
Display Floating Point:
Select this check box to display the decimal point.
If
Data Type
is
BIN16(+)
,
BIN16(+/-)
,
BIN32(+)
,
BIN32(+/-)
,
BCD4
, or
BCD8
and the
Display
Floating Point
check box is selected, a decimal value will be displayed on the Numerical Input when a
decimal value is entered on the keypad in entry mode, but an integer is written to the device. In display
mode, source data is an integer, but the value is displayed with a decimal point added at the number of
floating digits configured for the Numerical Input.
However, if
float32
is selected for
Data Type
, both the destination data and the source data are decimal
values.
Example: When
Display Type
is configured as
Decimal, Data Type
is
BIN16(+)
, the
Display Floating
Point
check box is selected,
Digits
is 5,
Floating Digits
is 3, and
Destination Device
is D100
External device
Touch
12.345
D100:
12345
12.345
Floating Digits:
Specifies the number of digits for the fractional part of the decimal value out of the
number of digits specified by
Digits
.
This option can only be configured when the
Display Floating Point
check box is
selected. The range of digits that can be set for the fractional part varies based on the
display type and data type. The range of digits that can be set for the fractional part is as
follows.
Display Type
Data Type
Floating Digits
Decimal display
BIN16 (+), BIN16 (+/-)
1 to Digits
BIN32 (+), BIN32 (+/-)
1 to Digits
BCD4
1 to Digits
BCD8
1 to Digits
float32
1 to 8
Hexadecimal
display
BIN16 (+)
--
BIN32 (+)
--
Summary of Contents for SmartAXIS Touch FT1A Series
Page 1: ...FT1A Series FT9Y B1390 4 SmartAXIS Touch User s Manual ...
Page 22: ...Contents Preface 21 SmartAXIS Touch User s Manual ...
Page 240: ...6 Using Library Screens 4 36 SmartAXIS Touch User s Manual ...
Page 416: ...2 Multi State Lamps 8 26 SmartAXIS Touch User s Manual ...
Page 558: ...9 Calendar 9 142 SmartAXIS Touch User s Manual ...
Page 668: ...6 Timer 11 52 SmartAXIS Touch User s Manual ...
Page 754: ...4 Using Data and Detected Alarms 13 34 SmartAXIS Touch User s Manual ...
Page 792: ...4 Using the Data 14 38 SmartAXIS Touch User s Manual ...
Page 810: ...4 Using the Data 15 18 SmartAXIS Touch User s Manual ...
Page 870: ...3 Text Manager 19 16 SmartAXIS Touch User s Manual ...
Page 924: ...6 Important Notes 20 54 SmartAXIS Touch User s Manual ...
Page 1036: ...5 User Communication 22 74 SmartAXIS Touch User s Manual ...
Page 1092: ...2 Monitoring on the Touch 24 26 SmartAXIS Touch User s Manual ...
Page 1142: ...2 Word Devices 27 18 SmartAXIS Touch User s Manual ...
Page 1186: ...2 Analog Cartridge 29 34 SmartAXIS Touch User s Manual ...
Page 1194: ...3 Handling Problems 30 8 SmartAXIS Touch User s Manual ...