SmartAXIS Touch User's Manual
22-35
5 User Communication
22
Communication
■
Command Size
Displays the data size of a configured command.
The calculation method for command size varies based on the type selected in
Command Type
on the Command
Settings dialog box. The command size calculation methods are as follows.
■
OK
Save the settings.
■
Cancel
Cancel the saving of settings.
BCC:
Displays the specified data enclosed in BCC
( ).
BCC(Calculation Start Position Calculation End Position Calculation Type
Conversion Type Number of bytes)
Calculation Start Position:
Displays the data position where the BCC calculation
starts.
Calculation End Position:
Displays the data position where the BCC calculation ends.
Calculation Type:
Display the methods to calculate the data between the
Calculation Start Position and Calculation End Position as
follows.
XOR: When
XOR
is selected
ADD: When
ADD
is selected
ADD2: When
ADD
(2's Complement)
is selected
Conversion Type:
Display the conversion methods for values of devices as
follows.
B16-A: When
Binary (HEX)
to
ASCII
is selected
N: When
No Conversion
is selected
Number of bytes:
Displays the number of bytes of the transmitted or
received data.
Example: BCC(2 1 XOR N 2)
Skip:
Displays the specified data enclosed in Skip( ).
Skip(Number of bytes)
Example: Skip(2)
Edit
Add or change data.
To add data, select an empty line in the Command, and then click this button. To
change data, select data in the Command, and then click this button. For details, refer
to “Data Settings Dialog Box” on page 22-36.
Insert
Insert data at the position of the selected command.
Click this button to display the Data Settings dialog box. And specify the data. The data
at the insertion point shifts down by 1 item. When 32 data items are already set, you
cannot insert data.
Delete
Deletes the selected data.
Up
Shifts the selected data upward in the command.
Down
Shifts the selected data downward in the command.
TXD:
Number of bytes for Constant Data + Number of bytes for a data of Registering Co Number of
bytes of BCC + Number of bytes of Device x Words of Device
RXD:
Number of bytes for Constant Data + Number of bytes for a data of Registering Co Number of
bytes of BCC + Number of bytes of Skip + Number of bytes of Device x Words of Device
Summary of Contents for SmartAXIS Touch FT1A Series
Page 1: ...FT1A Series FT9Y B1390 4 SmartAXIS Touch User s Manual ...
Page 22: ...Contents Preface 21 SmartAXIS Touch User s Manual ...
Page 240: ...6 Using Library Screens 4 36 SmartAXIS Touch User s Manual ...
Page 416: ...2 Multi State Lamps 8 26 SmartAXIS Touch User s Manual ...
Page 558: ...9 Calendar 9 142 SmartAXIS Touch User s Manual ...
Page 668: ...6 Timer 11 52 SmartAXIS Touch User s Manual ...
Page 754: ...4 Using Data and Detected Alarms 13 34 SmartAXIS Touch User s Manual ...
Page 792: ...4 Using the Data 14 38 SmartAXIS Touch User s Manual ...
Page 810: ...4 Using the Data 15 18 SmartAXIS Touch User s Manual ...
Page 870: ...3 Text Manager 19 16 SmartAXIS Touch User s Manual ...
Page 924: ...6 Important Notes 20 54 SmartAXIS Touch User s Manual ...
Page 1036: ...5 User Communication 22 74 SmartAXIS Touch User s Manual ...
Page 1092: ...2 Monitoring on the Touch 24 26 SmartAXIS Touch User s Manual ...
Page 1142: ...2 Word Devices 27 18 SmartAXIS Touch User s Manual ...
Page 1186: ...2 Analog Cartridge 29 34 SmartAXIS Touch User s Manual ...
Page 1194: ...3 Handling Problems 30 8 SmartAXIS Touch User s Manual ...