WindO/I-NV4 User’s Manual
14-11
2 Data Log Function Configuration Procedure
14
Data Log Function
11
In
Label
, enter the text to display for the label of the data.
The label is used for the label row of the data number columns when the data is output as CSV.
• When
Number of Data
is 2 or higher, "Data+Number" is automatically entered.
Example: Data001, Data002, Data003
• If the
Use Text Manager
check box is selected on the
Data
tab, specify a text ID to use for the label in
Label(Start Text ID)
.
12
In
Top Device Address
, specify the starting device address of the word devices that will be read for sampling data.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-68.
13
Select the data type of the sampled device value in
Data Type
.
The data type selected here is the data type for the numerical values when the data is output as CSV.
When
String(S)
is selected, use
Words
to specify the number of words of device addresses to read starting from the
set device address and proceed to step
15
. The set number of words of consecutive device addresses from the
starting device address will be output as CSV.
14
Under
Display Type
, set the display type for numerical values when data is output as CSV.
■
Counting Method
Select the display type as
Decimal
or
Hexadecimal
for numerical values.
■
Digits
Specifies the digits to display. The range of digits that can be set varies based on the display type and data type.
■
Display Floating Point
Select this check box to display the decimal point.
■
Floating Digits
Specifies the number of digits for the fractional part of the decimal value out of the number of digits specified by
Digits
.
This option can only be configured when the
Display Floating Point
check box is selected.
■
Floating Symbol
Selects the decimal point symbol from the following.
.(dot)
,
:(colon)
,
;(semicolon)
,
,(comma)
,
/(slash)
This option can only be configured when the
Display Floating Point
check box is selected.
15
Click
OK
to close the
Add Data
dialog box.
You are returned to the
Individual Settings
dialog box.
To individually register Data Log settings, repeat steps
9
through
14
.
Summary of Contents for MICRO/I HG4G-CJT22 F-B Series
Page 1: ...B 1701 11 User s Manual ...
Page 26: ...Preface 25 WindO I NV4 User s Manual ...
Page 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Page 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Page 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Page 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Page 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Page 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Page 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Page 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Page 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Page 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Page 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Page 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Page 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Page 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Page 1664: ...Index 12 WindO I NV4 User s Manual ...