WindO/I-NV4 User’s Manual
20-25
4 Script Definition Method
20
Script
Data comparison and copy
Character string operation
Only internal devices can be specified as an argument for character string operation function.
Termination character NULL (0x00) is treated as end of character string when character string is handled. Also,
termination character NULL is not included in the length of the character string.
Function
Format
Description
Data
comparison
MEMCMP(
,
,
)
: Beginning device address of comparison target 1
: Beginning device address of comparison target 2
: Range of comparison (in words)
Values of device address
for
words and values of device
address
for
words are compared.
1 is returned if all the values of device addresses match, and 0 is
returned if any of the value does not match.
• Specified range is compared in word unit, and result is returned.
• Up to 64 words can be compared.
Data copy
MEMCPY(
,
,
)
: Beginning device address of copy source
: Beginning device address of copy target
: Range of copy (in words)
Values of device address from
for
words are copied to
for
words respectively.
• Specified range is copied in word unit.
• Up to 64 words can be copied.
Function
Format
Description
Character
string copy
STRCUT(
,
,
,
)
: Beginning device address of copy target
: Beginning device address containing copy source
character string
: Start location of copy (0-127)
: Number of characters to copy (1-128)
From the character string starting from
, character string
from
bytes forward for
characters are stored into
for
characters.
Character
number count
STRLEN(
)
Number of characters for character string starting from
is
returned.
Character
string
concatenation
STRCAT(
,
)
To the character string starting from
, the character string
starting from
is concatenated, and
is returned to
beginning.
Character
string search
STRSTR(
,
)
From the character string starting from
, character string
starting from
is searched, and location found (number of
characters from beginning -1) is returned.
• Maximum number for character string to search is 128
characters.
a
b
c
a
b
c
a
c
b
c
a
b
c
a
b
c
a
c
b
c
a
b
c
d
a
b
c
d
b
c
d
a
d
a
a
a
b
a
b
a
a
b
a
b
Summary of Contents for MICRO/I HG4G-CJT22 F-B Series
Page 1: ...B 1701 11 User s Manual ...
Page 26: ...Preface 25 WindO I NV4 User s Manual ...
Page 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Page 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Page 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Page 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Page 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Page 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Page 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Page 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Page 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Page 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Page 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Page 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Page 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Page 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Page 1664: ...Index 12 WindO I NV4 User s Manual ...