1 Numerical Input
10-18
WindO/I-NV4 User’s Manual
■
Visible Condition
The Numerical Input is displayed while the condition is satisfied. The Numerical Input is hidden while the condition is
not satisfied.
While OFF:
Enables the Numerical Input when the value of device address is 0.
While satisfying the condition: Enables the Numerical Input when the condition is satisfied.
Data Type:
Selects the type of data handled by the conditional expression for the input condition.
This option can only be configured if
While satisfying the condition
is selected for
Trigger Type
.
For details, refer to Chapter 2 “1.1 Available Data” on page 2-1.
Device Address: Specifies the bit device or the bit number of the word device to serve as the input condition.
This option can only be configured when
While ON
or
While OFF
is selected for
Trigger Type
.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2
“5.1 Device Address Settings” on page 2-68.
Condition:
Specifies the conditional expression for the input condition.
This option can only be configured when
While satisfying the condition
is selected for
Trigger
Type
.
Click
to display the
Trigger Condition Settings
dialog box. For the conditional expression
configuration procedure, refer to Chapter 2 “5.2 Setting Conditional Expressions” on page 2-71.
Comment:
Used for entering a comment for the input condition. The maximum number is 80 characters.
1
0
Enabled
Enabled
Enabled
Disabled
Disabled
Disabled
Value of
Device Address
Numerical
Input state
123
123
123
123
123
123
Satisfied
Not satisfied
Disabled
Disabled
Disabled
Enabled
Enabled
Enabled
Numerical
Input state
Condition
123
123
123
123
123
123
Example: When
Trigger Type
is
While ON
and
Device Address
is
LM0
While LM0 is 0, the condition is not satisfied and the Numerical Input is hidden.
While LM0 is 1, the condition is satisfied and the Numerical Input is displayed.
LM0:
MICRO/I
0
LM0: 1
Show
Condition
Not
satisfied
Condition
Satisfied
123
Hide
• If the Numerical Input is hidden while entering a value, the input is canceled. If a popup screen
configured as the standard keypad or a keypad is displayed, these screens are closed.
• When multiple Numerical Inputs are arranged on the screen and the
Focus is moved by ENT button
check box is selected, entry mode is canceled if the Numerical Input is hidden while entering a value.
Summary of Contents for MICRO/I HG4G-CJT22 F-B Series
Page 1: ...B 1701 11 User s Manual ...
Page 26: ...Preface 25 WindO I NV4 User s Manual ...
Page 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Page 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Page 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Page 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Page 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Page 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Page 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Page 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Page 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Page 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Page 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Page 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Page 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Page 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Page 1664: ...Index 12 WindO I NV4 User s Manual ...