WindO/I-NV4 User’s Manual
10-65
3 Picture Display
10
Data Displa
ys
■
Range of Value
Configures the range of values to read from the Source Device Address with a fixed value or a value of device
address.
Converts the read value to the specified angle range, and then rotate the picture.
This option can only be configured when the
Use Custom Settings
check box is selected. When the
Use Custom
Settings
check box is cleared. only the
Maximum
can be specified with a fixed value.
Specifies the range of values that corresponds to the range of angle.
■
Range of Angle
Configures the range of the rotation angle with a fixed value or a value of device address. This option can only be
configured when the
Use Custom Settings
check box is selected.
Specifies the range of angle for rotation.
Value:
Specifies as constants.
Device Address:
Specifies as the values of word devices.
Minimum, Maximum: Specifies the minimum and maximum values.
If
Value
is selected, the minimum and maximum values that can be specified will depend on
the data type selected by
Data Type
. For details about data types, refer to Chapter 2 “1.1
If
Device Address
is selected, specify the word device to be read. Click
to display the Tag
Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device Address
Settings” on page 2-68.
When the Minimum is bigger than the Maximum, the picture is not rotated.
Value:
Specifies as constants.
Device Address:
Specifies as the values of word devices.
Start, End:
Specifies the start angle of rotation (-360° to 360°) and the end angle of rotation (-360° to
360°).
If
Value
is selected, the start and end angles that can be specified will depend on the data
type selected by
Data Type
. For details about data types, refer to Chapter 2 “1.1 Available
If
Device Address
is selected, specify the word device to be read. Click
to display the Tag
Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device Address
Settings” on page 2-68.
The direction of rotation is as follows.
Start angle < End angle: Clockwise
Start angle > End angle: Counterclockwise
Summary of Contents for MICRO/I HG4G-CJT22 F-B Series
Page 1: ...B 1701 11 User s Manual ...
Page 26: ...Preface 25 WindO I NV4 User s Manual ...
Page 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Page 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Page 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Page 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Page 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Page 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Page 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Page 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Page 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Page 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Page 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Page 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Page 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Page 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Page 1664: ...Index 12 WindO I NV4 User s Manual ...