7 Alarm List Display
10-140
WindO/I-NV4 User’s Manual
●
List
Tab
The
List
tab is only displayed when
New Message List
is selected for
Message Settings
on the
General
tab.
■
Number of Blocks
Configures the device addresses that trigger messages to display and message switching as blocks (1 to 64).
■
Start Text ID
Specifies the Text Manager ID number (1 to 32000) of the message to display. The text ID numbers are sequentially
configured for all channels from the first block starting with the ID number configured here. Click
to display Text
Manager.
■
Device Address Setting Method
Selects the trigger device address setting method.
■
(Block settings)
Registers and edits the messages to display for each block channel.
(Block settings)
1 block is composed of 16 channels. 1 device address bit can be monitored for each channel. The maximum
number of device address bits that can be monitored is 16 for each block.
Serial:
The trigger device addresses after the block number selected in the block settings are configured
with sequential addresses.
Random:
Configures trigger device addresses for each block number.
Block No.:
Shows the block numbers in the amount specified by
Number of Blocks
.
Double clicking the cell displays the
Individual Settings
dialog box. For details, refer to
“Individual Settings Dialog Box” on page 10-141.
Trigger Device Address: Shows the word device to use as the condition to display messages.
Double clicking the cell displays the Tag Editor. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-68.
When
Serial
is selected for
Device Address Setting Method
, the trigger device
addresses for block numbers after the selected block number are automatically configured
with the configured trigger device address as the starting address.
No. of Reg. Text:
Shows the number of messages registered to the block.
Double clicking the cell displays the
Individual Settings
dialog box. For details, refer to
“Individual Settings Dialog Box” on page 10-141.
Edit:
Changes the block settings in list.
Select a block number in the list and click this button to display the
Individual Settings
dialog box. For details, refer to “Individual Settings Dialog Box” on page 10-141.
Summary of Contents for MICRO/I HG4G-CJT22 F-B Series
Page 1: ...B 1701 11 User s Manual ...
Page 26: ...Preface 25 WindO I NV4 User s Manual ...
Page 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Page 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Page 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Page 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Page 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Page 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Page 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Page 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Page 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Page 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Page 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Page 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Page 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Page 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Page 1664: ...Index 12 WindO I NV4 User s Manual ...