2 Character Input
10-30
WindO/I-NV4 User’s Manual
■
Data Format
Specifies the digits to display.
■
Input Method
These options configure the destination for the character codes for the entered text.
*1 Advanced mode only
Coordinates X, Y:
Specifies the display location of the popup screen configured as the keypad.
With the upper-left corner of the screen as the origin, the X and Y coordinates are the
upper-left corner of the popup screen.
This option can only be configured when
Standard(Half-Width Character)
,
Standard(Hiragana)
or
Popup
is selected for
Type
and the
Adjust location
automatically
check box is cleared.
Specify the coordinates in 1 dot units.
X: 0 to (base screen horizontal size - 1)
Y: 0 to (base screen vertical size - 1)
Input Digits:
Specifies the number of digits that can be entered with the Character Input (1 to 127). For
each character to enter, one digit for half-width characters and two digits for full-width
characters is required.
Display Digits:
Specifies the number of digits that can be displayed in the Character Input display (1 to 100).
Regardless of half-width or full-width, one digit is required per character.
Destination Device Address:
Specifies the destination word device for the character codes for the entered text.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-68.
Use Reference Device Address
:
Select this check box and specify a device address to change the destination word device by the value of this
device address.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-68.
For details on indirect writing, refer to Chapter 2 “Indirect Read and Indirect Write Settings” on page 2-5.
Write NULL (0x00) after the end of the string:
Select this check box to write NULL (0x00) to all device addresses from the end of the string to the address
number specified by
Input Digits
if the length of the input string is less than
Input Digits
.
Example: If
Input Digits
is 10 and a string with a length of 5 was input
4847
(Hex)
‘H’ ‘G’
2053
(Hex)
4552
(Hex)
4943
(Hex)
5300
(Hex)
‘ ’ ‘S’
‘E’ ‘R’
‘ I ’ ‘E’
‘S’
(NULL)
4847
(Hex)
‘H’ ‘G’
2053
(Hex)
4552
(Hex)
4943
(Hex)
5300
(Hex)
‘ ’ ‘S’
‘E’ ‘R’
‘ I ’ ‘E’
‘S’
(NULL)
4D49
(Hex)
‘M’ ‘I’
4352
(Hex)
4F00
(Hex)
4943
(Hex)
5300
(Hex)
‘C’ ‘R’
‘O’
(NULL)
‘ I ’ ‘E’
‘S’
(NULL)
4D49
(Hex)
‘M’ ‘I’
4352
(Hex)
4F00
(Hex)
0000
(Hex)
0000
(Hex)
‘C’ ‘R’
‘O’
(NULL)
(NULL)(NULL)
(NULL)(NULL)
Enter MICRO
(Length of the string is 5)
Check box: Selected
Check box: Cleared
Character Input
display
MICRO_
Value of
destination
device address
HG SERIES
MICRO
MICRO_
HG SERIES
MICRO
Character Input
display
Value of
destination
device address
Values updated
to 6th character
NULL (0x00) is written
from 7th character
and the values of
all 10 characters
are updated
Values are not
updated
Summary of Contents for MICRO/I HG4G-CJT22 F-B Series
Page 1: ...B 1701 11 User s Manual ...
Page 26: ...Preface 25 WindO I NV4 User s Manual ...
Page 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Page 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Page 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Page 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Page 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Page 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Page 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Page 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Page 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Page 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Page 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Page 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Page 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Page 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Page 1664: ...Index 12 WindO I NV4 User s Manual ...